Vi gir deg det siste innen robotikk, kontrollteknologi og drivteknologi. Velg mellom et bredt spekter av produkter og tjenester som er både innovative og skalerbare. Vi lager komplette løsninger på dine vilkår.
SLIO
FM 050 - Counter Module - 050-1BA10
The Smart Control and I/O System
Yaskawa Norway Produkter PLC SLIO FM 050 - Counter Module - 050-1BA10
Overview
FM 050 - Function Module - 050-1BA10
Ordercode: 050-1BA10
- 1x Counter 32 Bit (AB), DC 5 V
- Up to 2 MHz (difference signal)
Technical Details
- Input power supply
- x No
- Input Voltage
- x No
- Current Consumption
- x No
- Max. current drain at backplane bus
- x No
- Max. current drain load supply
- x No
- Current consumption from backplane bus
- 75 mA
- Current consumption from load voltage L+ (without load)
- x No
- Power Loss
- 0.85 W
- Number of inputs (digital)
- x No
- Rated load voltage (digital)
- DC 20.4 - 28.8 V
- Current consumption from load voltage L+ (without load)
- 20 mA
- Signal logic input (digital)
- x No
- Input characteristic curve (digital)
- x No
- Initial data size (digital)
- 64 bit
- Number of outputs (digital)
- x No
- Rated load voltage (digital output)
- x No
- Current consumption from load voltage L+ (without load)
- x No
- Signal logic output (digital)
- x No
- Output data size (digital)
- 80 bit
- Number of inputs (analog)
- x No
- Rated load voltage (analog)
- x No
- Current consumption from load voltage L+ (without load)
- x No
- Voltage inputs (analog)
- x No
- Current inputs (analog)
- x No
- Resolution in bit
- x No
- Measurement principle
- x No
- Basic conversion time
- x No
- Initial data size
- x No
- Number of outputs (analog)
- x No
- Output voltage ranges
- x No
- Output current ranges
- x No
- Resolution in bit (analog)
- x No
- Conversion time (analog)
- x No
- Output data size (analog)
- x No
- Number of counters
- 1
- Counter width
- 32 bit
- Maximum input frequency
- 500 kHz
- Maximum count frequency
- 2000 kHz
- Maximum count frequency
- 2000 kHz
- Maximum count frequency
- 2000 kHz
- Maximum count frequency
- 2000 kHz
- Number of channels
- x No
- Input voltage (rated value)
- x No
- Power stage
- x No
- PWM frequency
- x No
- Type of encoder
- x No
- Encoder frequency
- x No
- Encoder resolution (internal)
- x No
- Control type
- x No
- Terminal voltage max.
- x No
- Terminal current max.
- x No
- Total current per module, max.
- x No
- Number of clamps
- x No
- Binding of potential
- x No
- Point-to-point protocol
- x No
- Encoder Supply: Number of outputs (L+n)
- x No
- Rated output current
- x No
- Port mode
- x No
- Load memory, integrated
- x No
- Work memory, integrated
- x No
- Work memory, maximal
- x No
- Memory card slot
- x No
- Racks, max.
- x No
- Modules per rack, max.
- x No
- Fieldbus
- x No
- Connector
- x No
- Topology
- x No
- Transmission speed, max.
- x No
- Address range inputs, max.
- x No
- Address range outputs, max.
- x No
- Material
- PPE / PPE GF10
- Mounting
- Profile rail 35 mm
- Weight
- 12.9 mm
- Height
- 109 mm
- Depth
- 76.5 mm
- Net weight
- 58 g
- Gross weight
- 72 g
- Certifications
- UL certification, ChinaRoHS certification, UKCA certification, KC certification
- Safety protocol
- x No
- Safety requirements
- x No
- Circuit monitoring
- x No
- Max. operating temperature
- 60 °C
Downloads
Name | |||
FM 050 - Function Module - 050-1BA10
Datasheet for SLIO Function module 050-1BA10 Data sheet | English |
Data sheet | English | |
FM 050 - Funktionsmodul - 050-1BA10
Datenblatt für SLIO Funktionsmodul 050-1BA10 Data sheet | German |
Data sheet | German | |
FM 050-1BA10 - Zähler-Modul
Rev. 24-30 || SLIO FM 050-1BA10 (Zähler-Modul 5V Differential 1x32Bit) || HW: 01 Technical documentation | German |
Technical documentation | German | |
FM 050-1BA10 - Counter module
Rev. 24-30 || SLIO FM 050-1BA10 (Counter module 5V differential 1x32Bit) || HW: 01 Technical documentation | English |
Technical documentation | English | |
System SLIO - Liste der Stromaufnahmen
Rev. 24-36 || SLIO Liste der Stromaufnahmen der System SLIO Module Technical documentation | German |
Technical documentation | German | |
System SLIO - List of current consumptions
Rev. 24-36 || SLIO List of the current consumptions of the System SLIO modules Technical documentation | English |
Technical documentation | English | |
System SLIO - Kompatibilitätsliste
Rev. 24-25 || SLIO System SLIO CPUs, System SLIO IMs, Taktsynchronität Technical documentation | German |
Technical documentation | German | |
System SLIO - Compatibility list
Rev. 24-25 || SLIO System SLIO CPUs, System SLIO IMs, Isochronous mode Technical documentation | English |
Technical documentation | English | |
EU-Declaration of Conformity - SLIO
state: 03.03.2020 Certification | German, English |
Certification | German, English | |
UL SLIO
Vol1 Sec2 Certification | English |
Certification | English | |
UK-Declaration of Conformity - SLIO
state: 10.09.2024 Certification | English |
Certification | English | |
EU-Declaration of Conformity - SLIO
state: 10.09.2024 Certification | English, German |
Certification | English, German | |
YASKAWA Controls MTBF Technical documentation | English | Technical documentation | English | |
3D-Data SLIO Module 8x
SLIO Module 8 contact points / SLIO Module 8 point terminal CAD/CAE | English, German |
CAD/CAE | English, German | |
Yaskawa System Slio | ChinaRoHS Certification | | Certification | ||
SLIO Labeling Stripes
To print approximately the same labeling stripes as the original, it is best to use chromosulphate board with 300g sheet weight. Technical documentation | English |
Technical documentation | English | |
System SLIO Ersatzteile Technical documentation | German | Technical documentation | German | |
System SLIO Spare Parts Technical documentation | English | Technical documentation | English | |
SLIO - Das dezentrale I/O-System
SLIO (= Sliced I/O) ist ein modular aufgebautes und kompaktes, dezentrales I/O-System. Brochures | German |
Brochures | German | |
SLIO - The decentralized I/O system
SLIO (= sliced I/O) is a modular and extremely compact, decentralized I/O system. Brochures | English |
Brochures | English |